Littelfuse, founded in 1927 and headquartered in Chicago, Illinois, is a global industrial technology manufacturer serving more than 100,000 customers across 15-plus countries. The company wanted a standardised Industry 4.0 rollout across its factories with minimal capital investment, on equipment that was never designed to be connected.
Ageing equipment, manual processes
Many processes were manual and the installed base was mixed, so problems on the floor were difficult to analyse with any speed.
Root cause analysis took over a week
Report generation was slow enough that findings arrived long after the event they described.
Weak equipment KPIs
OEE, MTBF, MTBA and MTTR were all below where the plant wanted them, with no live view to work against.
Mixed controls, minimal spend
The rollout had to cover Allen Bradley and GE Fanuc PLCs and industrial PCs without replacing machines.
Cantier as Littelfuse’s Industry 4.0 partner
A proof of concept in 2019 connected eight machines around OEE and machine status monitoring. Productivity rose 15% in four weeks, and the wider rollout followed.
“We had a very good experience with Cantier on MES 4.0 and SCADA implementation in our facility. Some of our machines are as old as 45 years and we thought it would be difficult to connect them to get live data, but the Cantier team proved us wrong. We have seen a 7% improvement in OEE and 17% improvement in MTTR within three months of installation.”
Prasad Reddy, Senior Director of Manufacturing
- 01
Machine connectivity at scale
An IIoT gateway on the OPC UA standard connected 127 machines at one electronics factory, including machines more than 40 years old, without replacing the installed base.
- 02
Digital dashboard with real time OEE
Colour coded, drill down views of availability, performance and quality, with historical trends, so teams can see which line needs attention first rather than reading a report.
“The colour coding helps us prioritise issues and drill down for detail. With the trends and analysis, we can predict issues in advance.” — Richard Tacla, Engineering Manager
- 03
Faster response and recovery
Downtime is monitored automatically and alerts are immediate. Report generation moved from more than a week to a single click.
“Previously it took more than a week to produce the Analysis Report. Now we generate it in one click, which helps us make immediate decisions.” — Nolito Valeros, Plant Maintenance Manager
- 04
Maintenance KPIs and predictive maintenance
MTTR, MTBF and MTBA dashboards sit alongside usage and condition based maintenance that raises work orders and alerts before a failure becomes downtime. With the volume of data now collected, Cantier is applying machine learning models to predict maintenance and quality issues ahead of time.
Measured results within three months
The figures below are the client’s own, recorded after the MES 4.0 and SCADA rollout at the electronics plant.
- 17% improvement in MTTR.
- 15% improvement in MTBF.
- 10% overall productivity improvement.
- 7% improvement in OEE.
- At least 15% reduction in front end equipment downtime, reported by the client.